DIP switch settings for the ICT XBA and XBA mini bill acceptors configured for US dollars.

How to read these tables. β˜… marks the manufacturer setting. A dash means that switch is not used by that setting β€” leave it where it is. A unit shipped from the factory has all switches OFF.

Power-cycle the acceptor after changing any switch. Settings are only read at startup.

XBA β€” USD6

Configuration part number: SWX8US60800-R Β Β·Β  Interfaces covered: Pulse, ICT002U, ICT104U, ICT104V, MDB

Main DIP switch settings β€” left switch block (SW1–SW8)

Applies to: all interfaces

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8
Reject $ 1 ON – – – – – – –
β˜… Accept $ 1 OFF – – – – – – –
Reject $ 5 – ON – – – – – –
β˜… Accept $ 5 – OFF – – – – – –
Reject $ 10 – – ON – – – – –
β˜… Accept $ 10 – – OFF – – – – –
Reject $ 20 – – – ON – – – –
β˜… Accept $ 20 – – – OFF – – – –
Reject $ 50 & 100 – – – – ON – – –
β˜… Accept $ 50 & 100 – – – – OFF – – –
Disable Bill Reject 4 Times BA Stop By 30 Sec – – – – – ON – –
β˜… Enable Bill Reject 4 Times BA Stop By 30 Sec – – – – – OFF – –
Stack Banknote when Power-up – – – – – – ON –
β˜… Reject Banknote when Power-up – – – – – – OFF –
Reserved – – – – – – – ON
β˜… Reserved – – – – – – – OFF

Main DIP switch settings β€” right switch block (SW1–SW8)

Applies to: Pulse / MDB / ICT104V

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8
β˜… Inhibit Active HIGH ON – – – – – – –
Inhibit Active LOW OFF – – – – – – –
Reserved – ON – – – – – –
β˜… Reserved – OFF – – – – – –
Reserved – – ON – – – – –
β˜… Reserved – – OFF – – – – –
Reserved – – – ON – – – –
β˜… Reserved – – – OFF – – – –
β˜… Credit-Pulse Normal HIGH | SCALING_FACTOR 100 DECIMAL_PLACE_OFF 2 | Connect with coin change – – – – ON – – –
Credit-Pulse Normal LOW | SCALING_FACTOR 1 DECIMAL_PLACE_OFF 0 | Connect with ICT JPSTD Converter board – – – – OFF – – –
β˜… Pulse Mode – – – – – ON – –
Other Mode – – – – – OFF – –
β˜… 1 pulse / USD 1 | MDB Mode – – – – – – OFF OFF
2 pulse / USD 1 | ICT002U Mode – – – – – – OFF ON
4 pulse / USD 1 | ICT104U Mode – – – – – – ON OFF
20 pulse / USD 1 | ICT104V Mode – – – – – – ON ON

Currency assign data (bill value channels)

Which denomination each bill-value channel reports, per interface. Channel numbering differs between interfaces β€” check the column for the interface you are using.

Bill value ICT002U ICT104U ICT104V Pulse MDB
BV1 USD 1 USD 1 USD 1 USD 1 USD 1
BV2 USD 5 USD 5 USD 5 USD 5 –
BV3 USD 10 USD 10 USD 10 USD 10 USD 5
BV4 USD 20 USD 20 USD 20 USD 20 USD 10
BV5 USD 50 USD 50 USD 50 USD 50 USD 20
BV6 USD 100 USD 100 USD 100 USD 100 USD 50
BV7 – – – – USD 100
Notes printed on the manufacturer sheet
  • β˜… Manufacture setting
  • Note : 1. After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • 2. Calibration card is needed.
  • This dip switch is located at the side of XBA.
  • This dip switch is located on the CPU board, remove the CPU board cover first.

XBA mini β€” USD6

Configuration part number: SWX2US60301-R Β Β·Β  Interfaces covered: Pulse, ICT104U, ICT104V, JPSTD, MDB

Main DIP switch settings (8-switch DIP + 4-switch DIP)

Applies to: all interfaces

↔ Swipe the table sideways to see every switch column.

Function / Setting 8-switch DIP 4-switch DIP
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW1 SW2 SW3 SW4
Reject USD 1 ON – – – – – – – – – – –
β˜… Accept USD 1 OFF – – – – – – – – – – –
Reject USD 5 – ON – – – – – – – – – –
β˜… Accept USD 5 – OFF – – – – – – – – – –
Reject USD 10 – – ON – – – – – – – – –
β˜… Accept USD 10 – – OFF – – – – – – – – –
Reject USD 20 – – – ON – – – – – – – –
β˜… Accept USD 20 – – – OFF – – – – – – – –
Reject USD 50 & 100 – – – – ON – – – – – – –
β˜… Accept USD 50 & 100 – – – – OFF – – – – – – –
Disable Bill Reject 4 Times BA Stop By 30 Sec – – – – – ON – – – – – –
β˜… Enable Bill Reject 4 Times BA Stop By 30 Sec – – – – – OFF – – – – – –
Colorful light – – – – – – OFF OFF – – – –
β˜… The green light flashes – – – – – – OFF ON – – – –
Reserved – – – – – – ON OFF – – – –
No light – – – – – – ON ON – – – –
Inhibit Active High – – – – – – – – ON – – –
β˜… Inhibit Active Low – – – – – – – – OFF – – –
Reserved – – – – – – – – – ON – –
β˜… Reserved – – – – – – – – – OFF – –
β˜… Interface Timing Conversion: 5ms LO / 5ms HI – – – – – – – – – – OFF OFF
Interface Timing Conversion: 5ms LO / 10ms HI – – – – – – – – – – ON OFF
Interface Timing Conversion: 10ms LO / 10ms HI – – – – – – – – – – OFF ON
Interface Timing Conversion: 20ms LO / 20ms HI – – – – – – – – – – ON ON

Interface settings β€” Pulse

Applies to: Pulse

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Credit-Pulse Normal HIGH ON – – –
Credit-Pulse Normal LOW OFF – – –
β˜… Pulse Mode – ON – –
Other Mode – OFF – –
β˜… 1 pulse / USD 1 – – OFF OFF
2 pulses / USD 1 – – OFF ON
4 pulses / USD 1 – – ON OFF
20 pulses / USD 1 – – ON ON

Interface settings β€” ICT104U

Applies to: ICT104U

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Reserved ON – – –
Reserved OFF – – –
Pulse Mode – ON – –
β˜… Other Mode – OFF – –
MDB Mode – – OFF OFF
JPSTD Mode – – OFF ON
β˜… ICT104U Mode – – ON OFF
ICT104V Mode – – ON ON

Interface settings β€” ICT104V

Applies to: ICT104V

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Connect with coin changer ON – – –
Connect with ICT JPSTD Converter board OFF – – –
Pulse Mode – ON – –
β˜… Other Mode – OFF – –
MDB Mode – – OFF OFF
JPSTD Mode – – OFF ON
ICT104U Mode – – ON OFF
β˜… ICT104V Mode – – ON ON

Interface settings β€” MDB

Applies to: MDB

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Scaling Factor (SF) = 100 Decimal Point Position (DPP) = 2 ON – – –
Scaling Factor (SF) = 1 Decimal Point Position (DPP) = 0 OFF – – –
Pulse Mode – ON – –
β˜… Other Mode – OFF – –
β˜… MDB Mode – – OFF OFF
JPSTD Mode – – OFF ON
ICT104U Mode – – ON OFF
ICT104V Mode – – ON ON

Currency assign data (bill value channels)

Which denomination each bill-value channel reports, per interface. Channel numbering differs between interfaces β€” check the column for the interface you are using.

Bill value ICT104U ICT104V JPSTD Pulse MDB
BV1 1 1 1 1 1
BV2 5 5 – 5 –
BV3 10 10 – 10 5
BV4 20 20 – 20 10
BV5 50 50 – 50 20
BV6 100 100 – 100 50
BV7 – – – – 100
Notes printed on the manufacturer sheet
  • β˜… Manufacture setting
  • Note : (1) After setting dip switch of the credit pulses, you should reset the bill acceptor again.
  • (2) Calibration card is needed.

Not sure which unit you have?

Denomination sets and interfaces vary by configuration part number, printed on the label on the side of the acceptor. Send us a photo of that label and we will confirm the exact model, firmware and correct switch settings β€” contact BillAcceptors.us.

Related

Transcribed from ICT manufacturer configuration sheets. We publish these as searchable tables because a printed switch chart is no use when you are standing at a machine. If you spot an error, tell us and we will fix it.