ICT A6E DIP Switch Settings (USD)
DIP switch settings for the ICT A6E bill acceptor configured for US dollars (part number SWERUS40200-R). The A6E is the current replacement for the discontinued ICT A6.
How to read these tables. β marks the manufacturer setting. A dash means that switch is not used by that setting β leave it where it is. A unit shipped from the factory has all switches OFF.
Power-cycle the acceptor after changing any switch. Settings are only read at startup.
Main DIP switch settings (8-switch DIP + 4-switch DIP)
β Swipe the table sideways to see every switch column.
| Function / Setting | 8-switch DIP | 4-switch DIP | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 | SW1 | SW2 | SW3 | SW4 | |
| Reject US$ 1 | ON | β | β | β | β | β | β | β | β | β | β | β |
| β Accept US$ 1 | OFF | β | β | β | β | β | β | β | β | β | β | β |
| Reject US$ 5 | β | ON | β | β | β | β | β | β | β | β | β | β |
| β Accept US$ 5 | β | OFF | β | β | β | β | β | β | β | β | β | β |
| Reject US$ 10 | β | β | ON | β | β | β | β | β | β | β | β | β |
| β Accept US$ 10 | β | β | OFF | β | β | β | β | β | β | β | β | β |
| Reject US$ 20 | β | β | β | ON | β | β | β | β | β | β | β | β |
| β Accept US$ 20 | β | β | β | OFF | β | β | β | β | β | β | β | β |
| High Acceptance | β | β | β | β | ON | β | β | β | β | β | β | β |
| β High Security | β | β | β | β | OFF | β | β | β | β | β | β | β |
| Interface(VCP) Mode (Note.3) | β | β | β | β | β | ON | β | β | β | β | β | β |
| β Diagnostic Mode (Note.4) | β | β | β | β | β | OFF | β | β | β | β | β | β |
| Harness Disable | β | β | β | β | β | β | ON | β | β | β | β | β |
| β Harness Enable | β | β | β | β | β | β | OFF | β | β | β | β | β |
| Inhibit Active High (Note.5) | β | β | β | β | β | β | β | ON | β | β | β | β |
| β Inhibit Active Low | β | β | β | β | β | β | β | OFF | β | β | β | β |
| β 1 pulse / US$ 1 | β | β | β | β | β | β | β | β | OFF | OFF | β | β |
| 2 pulses / US$ 1 | β | β | β | β | β | β | β | β | ON | OFF | β | β |
| 4 pulses / US$ 1 | β | β | β | β | β | β | β | β | OFF | ON | β | β |
| 20 pulses / US$ 1 | β | β | β | β | β | β | β | β | ON | ON | β | β |
| β Pulse Speed: 50ms LO / 50ms HI | β | β | β | β | β | β | β | β | β | β | OFF | OFF |
| Pulse Speed: 60ms LO / 300ms HI | β | β | β | β | β | β | β | β | β | β | ON | OFF |
| Pulse Speed: 30ms LO / 50ms HI | β | β | β | β | β | β | β | β | β | β | OFF | ON |
| Pulse Speed: 150ms LO / 150ms HI | β | β | β | β | β | β | β | β | β | β | ON | ON |
Interface settings β Pulse
β Swipe the table sideways to see every switch column.
| Function / Setting | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| β Credit-Pulse Normal HIGH | ON | β | β | β |
| Credit-Pulse Normal LOW | OFF | β | β | β |
| β Pulse Mode | β | ON | β | β |
| ICT002U Mode | β | OFF | β | β |
| Reserved | β | β | ON | β |
| β Reserved | β | β | OFF | β |
| Reserved | β | β | β | ON |
| β Reserved | β | β | β | OFF |
Interface settings β ICT002U
β Swipe the table sideways to see every switch column.
| Function / Setting | SW1 | SW2 | SW3 | SW4 |
|---|---|---|---|---|
| Reserved | ON | β | β | β |
| β Reserved | OFF | β | β | β |
| Pulse Mode | β | ON | β | β |
| β ICT002U Mode | β | OFF | β | β |
| Reserved | β | β | ON | β |
| β Reserved | β | β | OFF | β |
| Reserved | β | β | β | ON |
| β Reserved | β | β | β | OFF |
Currency assign data (bill value channels)
| Bill value | ICT | Pulse |
|---|---|---|
| BV1 | US$ 1 | US$ 1 |
| BV2 | US$ 5 | US$ 5 |
| BV3 | US$ 10 | US$ 10 |
| BV4 | US$ 20 | US$ 20 |
- β Manufacture setting
- β Default setting(Factory configuration has all switches in the OFF position.)
- Note : (1) Reset the bill acceptor after setting the dip switch.
- (2) SW7 and SW8 of the 8-switch DIP and the 4-switch DIP are for pulse protocol only.
- (3) Interface(VCP) Mode is for USB connection of ICT002U.
- (4) Diagnostic Mode is for USB connection of Autotest tool.
- (5) SW8 of the 8-switch DIP is for pulse 5V Enable only.
Not sure which unit you have?
Denomination sets and interfaces vary by configuration part number, printed on the label on the side of the acceptor. Send us a photo of that label and we will confirm the exact model, firmware and correct switch settings β contact BillAcceptors.us.