DIP switch settings for the ICT A6E bill acceptor configured for US dollars (part number SWERUS40200-R). The A6E is the current replacement for the discontinued ICT A6.

How to read these tables. β˜… marks the manufacturer setting. A dash means that switch is not used by that setting β€” leave it where it is. A unit shipped from the factory has all switches OFF.

Power-cycle the acceptor after changing any switch. Settings are only read at startup.

Configuration part number: SWERUS40200-R Β Β·Β  Interfaces covered: Pulse, ICT002U

Main DIP switch settings (8-switch DIP + 4-switch DIP)

Applies to: all interfaces

↔ Swipe the table sideways to see every switch column.

Function / Setting 8-switch DIP 4-switch DIP
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW1 SW2 SW3 SW4
Reject US$ 1 ON – – – – – – – – – – –
β˜… Accept US$ 1 OFF – – – – – – – – – – –
Reject US$ 5 – ON – – – – – – – – – –
β˜… Accept US$ 5 – OFF – – – – – – – – – –
Reject US$ 10 – – ON – – – – – – – – –
β˜… Accept US$ 10 – – OFF – – – – – – – – –
Reject US$ 20 – – – ON – – – – – – – –
β˜… Accept US$ 20 – – – OFF – – – – – – – –
High Acceptance – – – – ON – – – – – – –
β˜… High Security – – – – OFF – – – – – – –
Interface(VCP) Mode (Note.3) – – – – – ON – – – – – –
β˜… Diagnostic Mode (Note.4) – – – – – OFF – – – – – –
Harness Disable – – – – – – ON – – – – –
β˜… Harness Enable – – – – – – OFF – – – – –
Inhibit Active High (Note.5) – – – – – – – ON – – – –
β˜… Inhibit Active Low – – – – – – – OFF – – – –
β˜… 1 pulse / US$ 1 – – – – – – – – OFF OFF – –
2 pulses / US$ 1 – – – – – – – – ON OFF – –
4 pulses / US$ 1 – – – – – – – – OFF ON – –
20 pulses / US$ 1 – – – – – – – – ON ON – –
β˜… Pulse Speed: 50ms LO / 50ms HI – – – – – – – – – – OFF OFF
Pulse Speed: 60ms LO / 300ms HI – – – – – – – – – – ON OFF
Pulse Speed: 30ms LO / 50ms HI – – – – – – – – – – OFF ON
Pulse Speed: 150ms LO / 150ms HI – – – – – – – – – – ON ON

Interface settings β€” Pulse

Applies to: Pulse

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Credit-Pulse Normal HIGH ON – – –
Credit-Pulse Normal LOW OFF – – –
β˜… Pulse Mode – ON – –
ICT002U Mode – OFF – –
Reserved – – ON –
β˜… Reserved – – OFF –
Reserved – – – ON
β˜… Reserved – – – OFF

Interface settings β€” ICT002U

Applies to: ICT002U

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
Reserved ON – – –
β˜… Reserved OFF – – –
Pulse Mode – ON – –
β˜… ICT002U Mode – OFF – –
Reserved – – ON –
β˜… Reserved – – OFF –
Reserved – – – ON
β˜… Reserved – – – OFF

Currency assign data (bill value channels)

Which denomination each bill-value channel reports, per interface. Channel numbering differs between interfaces β€” check the column for the interface you are using.

Bill value ICT Pulse
BV1 US$ 1 US$ 1
BV2 US$ 5 US$ 5
BV3 US$ 10 US$ 10
BV4 US$ 20 US$ 20
Notes printed on the manufacturer sheet
  • β˜… Manufacture setting
  • β—‡ Default setting(Factory configuration has all switches in the OFF position.)
  • Note : (1) Reset the bill acceptor after setting the dip switch.
  • (2) SW7 and SW8 of the 8-switch DIP and the 4-switch DIP are for pulse protocol only.
  • (3) Interface(VCP) Mode is for USB connection of ICT002U.
  • (4) Diagnostic Mode is for USB connection of Autotest tool.
  • (5) SW8 of the 8-switch DIP is for pulse 5V Enable only.

Not sure which unit you have?

Denomination sets and interfaces vary by configuration part number, printed on the label on the side of the acceptor. Send us a photo of that label and we will confirm the exact model, firmware and correct switch settings β€” contact BillAcceptors.us.

Related

Transcribed from ICT manufacturer configuration sheets. We publish these as searchable tables because a printed switch chart is no use when you are standing at a machine. If you spot an error, tell us and we will fix it.

Newsletter