DIP switch settings for the ICT V7, V7E and LX7 bill acceptors configured for US dollars. The V7E and LX7 share the same configuration sheet.

How to read these tables. ★ marks the manufacturer setting. A dash means that switch is not used by that setting — leave it where it is. A unit shipped from the factory has all switches OFF.

Power-cycle the acceptor after changing any switch. Settings are only read at startup.

V7E/LX7 — USD6

Configuration part number: SWP5US60600-R  ·  Interfaces covered: Pulse, ICT002U, MDB, RS232 A0

Main DIP switch settings (8-switch DIP + 4-switch DIP)

Applies to: all interfaces

↔ Swipe the table sideways to see every switch column.

Function / Setting 8-switch DIP 4-switch DIP
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW1 SW2 SW3 SW4
Reject USD 1 ON – – – – – – – – – – –
★ Accept USD 1 OFF – – – – – – – – – – –
Reject USD 5 – ON – – – – – – – – – –
★ Accept USD 5 – OFF – – – – – – – – – –
Reject USD 10 – – ON – – – – – – – – –
★ Accept USD 10 – – OFF – – – – – – – – –
Reject USD 20 – – – ON – – – – – – – –
★ Accept USD 20 – – – OFF – – – – – – – –
Reject USD 50 & 100 – – – – ON – – – – – – –
★ Accept USD 50 & 100 – – – – OFF – – – – – – –
Reserved – – – – – ON – – – – – –
★ Reserved – – – – – OFF – – – – – –
Harness Disable – – – – – – ON – – – – –
★ Harness Enable – – – – – – OFF – – – – –
Inhibit Active High – – – – – – – ON – – – –
★ Inhibit Active Low – – – – – – – OFF – – – –
★ 1 pulse / USD 1 – – – – – – – – OFF OFF – –
2 pulses / USD 1 – – – – – – – – ON OFF – –
4 pulses / USD 1 – – – – – – – – OFF ON – –
20 pulses / USD 1 – – – – – – – – ON ON – –
★ Pulse Speed: 50ms LO / 50ms HI – – – – – – – – – – OFF OFF
Pulse Speed: 60ms LO / 300ms HI – – – – – – – – – – ON OFF
Pulse Speed: 30ms LO / 50ms HI – – – – – – – – – – OFF ON
Pulse Speed: 150ms LO / 150ms HI – – – – – – – – – – ON ON

Interface settings — Pulse

Applies to: Pulse

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
★ Pulse Normal High ON – – –
Pulse Normal Low OFF – – –
★ Pulse Mode – ON OFF –
ICT002U Interface – OFF ON –
MDB Interface – ON ON –
RS232 A0 Mode – OFF OFF –
Reserved – – – ON
★ Reserved – – – OFF

Interface settings — ICT002U

Applies to: ICT002U

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
Reserved ON – – –
★ Reserved OFF – – –
Pulse Mode – ON OFF –
★ ICT002U Interface – OFF ON –
MDB Interface – ON ON –
RS232 A0 Mode – OFF OFF –
Reserved – – – ON
★ Reserved – – – OFF

Interface settings — MDB

Applies to: MDB

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
★ Scaling Factor (SF) = 100 Decimal Point Position (DPP) = 2 ON – – –
Scaling Factor (SF) = 1 Decimal Point Position (DPP) = 0 OFF – – –
Pulse Mode – ON OFF –
ICT002U Interface – OFF ON –
★ MDB Interface – ON ON –
RS232 A0 Mode – OFF OFF –
Reserved – – – ON
★ Reserved – – – OFF

Interface settings — RS232 A0

Applies to: RS232 A0

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
Reserved ON – – –
★ Reserved OFF – – –
Pulse Mode – ON OFF –
ICT002U Interface – OFF ON –
MDB Interface – ON ON –
★ RS232 A0 Mode – OFF OFF –
Reserved – – – ON
★ Reserved – – – OFF

Currency assign data (bill value channels)

Which denomination each bill-value channel reports, per interface. Channel numbering differs between interfaces — check the column for the interface you are using.

Bill value Pulse RS232 A0 ICT002U MDB
BV1 USD 1 USD 1 USD 1 USD 1
BV2 USD 5 – USD 5 –
BV3 USD 10 USD 5 USD 10 USD 5
BV4 USD 20 USD 10 USD 20 USD 10
BV5 USD 50 USD 20 USD 50 USD 20
BV6 USD 100 USD 50 USD 100 USD 50
BV7 – USD 100 – USD 100
Notes printed on the manufacturer sheet
  • ★ Manufacture setting.
  • Note : (1) Default setting.
  • (2) Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
  • (3) Remove the front cover and the dip-switch in on the CPU board.
  • (Please refer to “SW1” setting.)

V7 — USD4

Configuration part number: SWV3US40100-R  ·  Interfaces covered: ICT004, Pulse, MDB

Main DIP switch settings (8-switch DIP + 4-switch DIP)

Applies to: all interfaces

↔ Swipe the table sideways to see every switch column.

Function / Setting 8-switch DIP 4-switch DIP
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW1 SW2 SW3 SW4
Reject USD 1 ON – – – – – – – – – – –
★ Accept USD 1 OFF – – – – – – – – – – –
Reject USD 5 – ON – – – – – – – – – –
★ Accept USD 5 – OFF – – – – – – – – – –
Reject USD 10 – – ON – – – – – – – – –
★ Accept USD 10 – – OFF – – – – – – – – –
Reject USD 20 – – – ON – – – – – – – –
★ Accept USD 20 – – – OFF – – – – – – – –
Reserved – – – – ON – – – – – – –
★ Reserved – – – – OFF – – – – – – –
Reserved – – – – – ON – – – – – –
★ Reserved – – – – – OFF – – – – – –
Harness Disable – – – – – – ON – – – – –
★ Harness Enable – – – – – – OFF – – – – –
Inhibit Active High – – – – – – – ON – – – –
★ Inhibit Active Low – – – – – – – OFF – – – –
★ 1 pulse / USD 1 – – – – – – – – OFF OFF – –
2 pulses / USD 1 – – – – – – – – ON OFF – –
4 pulses / USD 1 – – – – – – – – OFF ON – –
20 pulses / USD 1 – – – – – – – – ON ON – –
★ Pulse Speed: 50ms LO / 50ms HI – – – – – – – – – – OFF OFF
Pulse Speed: 60ms LO / 300ms HI – – – – – – – – – – ON OFF
Pulse Speed: 30ms LO / 50ms HI – – – – – – – – – – OFF ON
Pulse Speed: 150ms LO / 150ms HI – – – – – – – – – – ON ON

Interface settings — ICT004

Applies to: ICT004

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
Reserved ON – – –
★ Reserved OFF – – –
Pulse Mode – ON OFF –
MDB Interface – OFF OFF –
★ ICT004 Interface – OFF ON –
Reserved – ON ON –
Reserved – – – ON
★ Reserved – – – OFF

Interface settings — Pulse

Applies to: Pulse

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
★ Credit-Pulse Normal HIGH ON – – –
Credit-Pulse Normal LOW OFF – – –
★ Pulse Mode – ON OFF –
MDB Interface – OFF OFF –
ICT004 Interface – OFF ON –
Reserved – ON ON –
Reserved – – – ON
★ Reserved – – – OFF

Interface settings — MDB

Applies to: MDB

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
★ Scaling Factor (SF) = 100 Decimal Point Position (DPP) = 2 ON – – –
Scaling Factor (SF) = 1 Decimal Point Position (DPP) = 0 OFF – – –
Pulse Mode – ON OFF –
★ MDB Interface – OFF OFF –
ICT004 Interface – OFF ON –
Reserved – ON ON –
Reserved – – – ON
★ Reserved – – – OFF

Currency assign data (bill value channels)

Which denomination each bill-value channel reports, per interface. Channel numbering differs between interfaces — check the column for the interface you are using.

Bill value ICT004 Pulse MDB
BV1 USD 1 USD 1 USD 1
BV2 USD 5 USD 5 Reserved
BV3 USD 10 USD 10 USD 5
BV4 USD 20 USD 20 USD 10
BV5 – – USD 20
Notes printed on the manufacturer sheet
  • ★ Manufacture setting
  • ◇ Factory configuration has all switches in the OFF position.
  • Note: 1.Default setting.
  • 2.Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
  • 3.Remove the front cover and the dip-switch in on the CPU board.
  • (Please refer to “Sw1” setting.)

Not sure which unit you have?

Denomination sets and interfaces vary by configuration part number, printed on the label on the side of the acceptor. Send us a photo of that label and we will confirm the exact model, firmware and correct switch settings — contact BillAcceptors.us.

Related

Transcribed from ICT manufacturer configuration sheets. We publish these as searchable tables because a printed switch chart is no use when you are standing at a machine. If you spot an error, tell us and we will fix it.

Newsletter

A short sentence describing what someone will receive by subscribing

Add an image for this section