DIP switch settings for the ICT V7, V7E and LX7 bill acceptors configured for US dollars. The V7E and LX7 share the same configuration sheet.

How to read these tables. β˜… marks the manufacturer setting. A dash means that switch is not used by that setting β€” leave it where it is. A unit shipped from the factory has all switches OFF.

Power-cycle the acceptor after changing any switch. Settings are only read at startup.

V7E/LX7 β€” USD6

Configuration part number: SWP5US60600-R Β Β·Β  Interfaces covered: Pulse, ICT002U, MDB, RS232 A0

Main DIP switch settings (8-switch DIP + 4-switch DIP)

Applies to: all interfaces

↔ Swipe the table sideways to see every switch column.

Function / Setting 8-switch DIP 4-switch DIP
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW1 SW2 SW3 SW4
Reject USD 1 ON – – – – – – – – – – –
β˜… Accept USD 1 OFF – – – – – – – – – – –
Reject USD 5 – ON – – – – – – – – – –
β˜… Accept USD 5 – OFF – – – – – – – – – –
Reject USD 10 – – ON – – – – – – – – –
β˜… Accept USD 10 – – OFF – – – – – – – – –
Reject USD 20 – – – ON – – – – – – – –
β˜… Accept USD 20 – – – OFF – – – – – – – –
Reject USD 50 & 100 – – – – ON – – – – – – –
β˜… Accept USD 50 & 100 – – – – OFF – – – – – – –
Reserved – – – – – ON – – – – – –
β˜… Reserved – – – – – OFF – – – – – –
Harness Disable – – – – – – ON – – – – –
β˜… Harness Enable – – – – – – OFF – – – – –
Inhibit Active High – – – – – – – ON – – – –
β˜… Inhibit Active Low – – – – – – – OFF – – – –
β˜… 1 pulse / USD 1 – – – – – – – – OFF OFF – –
2 pulses / USD 1 – – – – – – – – ON OFF – –
4 pulses / USD 1 – – – – – – – – OFF ON – –
20 pulses / USD 1 – – – – – – – – ON ON – –
β˜… Pulse Speed: 50ms LO / 50ms HI – – – – – – – – – – OFF OFF
Pulse Speed: 60ms LO / 300ms HI – – – – – – – – – – ON OFF
Pulse Speed: 30ms LO / 50ms HI – – – – – – – – – – OFF ON
Pulse Speed: 150ms LO / 150ms HI – – – – – – – – – – ON ON

Interface settings β€” Pulse

Applies to: Pulse

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Pulse Normal High ON – – –
Pulse Normal Low OFF – – –
β˜… Pulse Mode – ON OFF –
ICT002U Interface – OFF ON –
MDB Interface – ON ON –
RS232 A0 Mode – OFF OFF –
Reserved – – – ON
β˜… Reserved – – – OFF

Interface settings β€” ICT002U

Applies to: ICT002U

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
Reserved ON – – –
β˜… Reserved OFF – – –
Pulse Mode – ON OFF –
β˜… ICT002U Interface – OFF ON –
MDB Interface – ON ON –
RS232 A0 Mode – OFF OFF –
Reserved – – – ON
β˜… Reserved – – – OFF

Interface settings β€” MDB

Applies to: MDB

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Scaling Factor (SF) = 100 Decimal Point Position (DPP) = 2 ON – – –
Scaling Factor (SF) = 1 Decimal Point Position (DPP) = 0 OFF – – –
Pulse Mode – ON OFF –
ICT002U Interface – OFF ON –
β˜… MDB Interface – ON ON –
RS232 A0 Mode – OFF OFF –
Reserved – – – ON
β˜… Reserved – – – OFF

Interface settings β€” RS232 A0

Applies to: RS232 A0

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
Reserved ON – – –
β˜… Reserved OFF – – –
Pulse Mode – ON OFF –
ICT002U Interface – OFF ON –
MDB Interface – ON ON –
β˜… RS232 A0 Mode – OFF OFF –
Reserved – – – ON
β˜… Reserved – – – OFF

Currency assign data (bill value channels)

Which denomination each bill-value channel reports, per interface. Channel numbering differs between interfaces β€” check the column for the interface you are using.

Bill value Pulse RS232 A0 ICT002U MDB
BV1 USD 1 USD 1 USD 1 USD 1
BV2 USD 5 – USD 5 –
BV3 USD 10 USD 5 USD 10 USD 5
BV4 USD 20 USD 10 USD 20 USD 10
BV5 USD 50 USD 20 USD 50 USD 20
BV6 USD 100 USD 50 USD 100 USD 50
BV7 – USD 100 – USD 100
Notes printed on the manufacturer sheet
  • β˜… Manufacture setting.
  • Note : (1) Default setting.
  • (2) Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
  • (3) Remove the front cover and the dip-switch in on the CPU board.
  • (Please refer to β€œSW1” setting.)

V7 β€” USD4

Configuration part number: SWV3US40100-R Β Β·Β  Interfaces covered: ICT004, Pulse, MDB

Main DIP switch settings (8-switch DIP + 4-switch DIP)

Applies to: all interfaces

↔ Swipe the table sideways to see every switch column.

Function / Setting 8-switch DIP 4-switch DIP
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW1 SW2 SW3 SW4
Reject USD 1 ON – – – – – – – – – – –
β˜… Accept USD 1 OFF – – – – – – – – – – –
Reject USD 5 – ON – – – – – – – – – –
β˜… Accept USD 5 – OFF – – – – – – – – – –
Reject USD 10 – – ON – – – – – – – – –
β˜… Accept USD 10 – – OFF – – – – – – – – –
Reject USD 20 – – – ON – – – – – – – –
β˜… Accept USD 20 – – – OFF – – – – – – – –
Reserved – – – – ON – – – – – – –
β˜… Reserved – – – – OFF – – – – – – –
Reserved – – – – – ON – – – – – –
β˜… Reserved – – – – – OFF – – – – – –
Harness Disable – – – – – – ON – – – – –
β˜… Harness Enable – – – – – – OFF – – – – –
Inhibit Active High – – – – – – – ON – – – –
β˜… Inhibit Active Low – – – – – – – OFF – – – –
β˜… 1 pulse / USD 1 – – – – – – – – OFF OFF – –
2 pulses / USD 1 – – – – – – – – ON OFF – –
4 pulses / USD 1 – – – – – – – – OFF ON – –
20 pulses / USD 1 – – – – – – – – ON ON – –
β˜… Pulse Speed: 50ms LO / 50ms HI – – – – – – – – – – OFF OFF
Pulse Speed: 60ms LO / 300ms HI – – – – – – – – – – ON OFF
Pulse Speed: 30ms LO / 50ms HI – – – – – – – – – – OFF ON
Pulse Speed: 150ms LO / 150ms HI – – – – – – – – – – ON ON

Interface settings β€” ICT004

Applies to: ICT004

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
Reserved ON – – –
β˜… Reserved OFF – – –
Pulse Mode – ON OFF –
MDB Interface – OFF OFF –
β˜… ICT004 Interface – OFF ON –
Reserved – ON ON –
Reserved – – – ON
β˜… Reserved – – – OFF

Interface settings β€” Pulse

Applies to: Pulse

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Credit-Pulse Normal HIGH ON – – –
Credit-Pulse Normal LOW OFF – – –
β˜… Pulse Mode – ON OFF –
MDB Interface – OFF OFF –
ICT004 Interface – OFF ON –
Reserved – ON ON –
Reserved – – – ON
β˜… Reserved – – – OFF

Interface settings β€” MDB

Applies to: MDB

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Scaling Factor (SF) = 100 Decimal Point Position (DPP) = 2 ON – – –
Scaling Factor (SF) = 1 Decimal Point Position (DPP) = 0 OFF – – –
Pulse Mode – ON OFF –
β˜… MDB Interface – OFF OFF –
ICT004 Interface – OFF ON –
Reserved – ON ON –
Reserved – – – ON
β˜… Reserved – – – OFF

Currency assign data (bill value channels)

Which denomination each bill-value channel reports, per interface. Channel numbering differs between interfaces β€” check the column for the interface you are using.

Bill value ICT004 Pulse MDB
BV1 USD 1 USD 1 USD 1
BV2 USD 5 USD 5 Reserved
BV3 USD 10 USD 10 USD 5
BV4 USD 20 USD 20 USD 10
BV5 – – USD 20
Notes printed on the manufacturer sheet
  • β˜… Manufacture setting
  • β—‡ Factory configuration has all switches in the OFF position.
  • Note: 1.Default setting.
  • 2.Use 2nd and 3rd dip of the internal dip-switch to change different interface protocol.
  • 3.Remove the front cover and the dip-switch in on the CPU board.
  • (Please refer to β€œSw1” setting.)

Not sure which unit you have?

Denomination sets and interfaces vary by configuration part number, printed on the label on the side of the acceptor. Send us a photo of that label and we will confirm the exact model, firmware and correct switch settings β€” contact BillAcceptors.us.

Related

Transcribed from ICT manufacturer configuration sheets. We publish these as searchable tables because a printed switch chart is no use when you are standing at a machine. If you spot an error, tell us and we will fix it.