DIP switch settings for the ICT PA7-E bill acceptor configured for US dollars (part number SWE0US62000-R). The PA7-E is the current replacement for the discontinued ICT PA7.

How to read these tables. β˜… marks the manufacturer setting. A dash means that switch is not used by that setting β€” leave it where it is. A unit shipped from the factory has all switches OFF.

Power-cycle the acceptor after changing any switch. Settings are only read at startup.

Configuration part number: SWE0US62000-R Β Β·Β  Interfaces covered: Pulse, NISR, ICT104U, 5V Enable

Main DIP switch settings (8-switch DIP + 4-switch DIP)

Applies to: all interfaces

↔ Swipe the table sideways to see every switch column.

Function / Setting 8-switch DIP 4-switch DIP
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW1 SW2 SW3 SW4
Reject US$ 1 ON – – – – – – – – – – –
β˜… Accept US$ 1 OFF – – – – – – – – – – –
Reject US$ 5 – ON – – – – – – – – – –
β˜… Accept US$ 5 – OFF – – – – – – – – – –
Reject US$ 10 – – ON – – – – – – – – –
β˜… Accept US$ 10 – – OFF – – – – – – – – –
Reject US$ 20 – – – ON – – – – – – – –
β˜… Accept US$ 20 – – – OFF – – – – – – – –
Reject US$ 50 & 100 – – – – ON – – – – – – –
β˜… Accept US$ 50 & 100 – – – – OFF – – – – – – –
Interface(VCP) Mode (Note.3) – – – – – ON – – – – – –
β˜… Diagnostic Mode (Note.4) – – – – – OFF – – – – – –
Harness Disable – – – – – – ON – – – – –
β˜… Harness Enable – – – – – – OFF – – – – –
Inhibit Active High – – – – – – – ON – – – –
β˜… Inhibit Active Low – – – – – – – OFF – – – –
β˜… 1 pulse / US$ 1 – – – – – – – – OFF OFF – –
2 pulses / US$ 1 – – – – – – – – ON OFF – –
4 pulses / US$ 1 – – – – – – – – OFF ON – –
20 pulses / US$ 1 – – – – – – – – ON ON – –
β˜… Pulse Speed: 50ms LO / 50ms HI – – – – – – – – – – OFF OFF
Pulse Speed: 60ms LO / 300ms HI – – – – – – – – – – ON OFF
Pulse Speed: 30ms LO / 50ms HI – – – – – – – – – – OFF ON
Pulse Speed: 150ms LO / 150ms HI – – – – – – – – – – ON ON

Interface settings β€” Pulse

Applies to: Pulse

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Credit-Pulse Normal HIGH ON – – –
Credit-Pulse Normal LOW OFF – – –
β˜… Pulse Mode – ON ON –
NISR Mode – OFF ON –
ICT104U Mode – ON OFF –
5V Enable Mode – OFF OFF –
Reserved – – – ON
β˜… Reserved – – – OFF

Interface settings β€” NISR

Applies to: NISR

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Send ERROR CODE ON – – –
No ERROR CODE OFF – – –
Pulse Mode – ON ON –
β˜… NISR Mode – OFF ON –
ICT104U Mode – ON OFF –
5V Enable Mode – OFF OFF –
Customized Mode – – – ON
β˜… Standard Mode – – – OFF

Interface settings β€” ICT104U

Applies to: ICT104U

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Reserved ON – – –
Reserved OFF – – –
Pulse Mode – ON ON –
NISR Mode – OFF ON –
β˜… ICT104U Mode – ON OFF –
5V Enable Mode – OFF OFF –
Reserved – – – ON
β˜… Reserved – – – OFF

Interface settings β€” 5V Enable

Applies to: 5V Enable

↔ Swipe the table sideways to see every switch column.

Function / Setting SW1 SW2 SW3 SW4
β˜… Credit-Pulse Normal HIGH ON – – –
Credit-Pulse Normal LOW OFF – – –
Pulse Mode – ON ON –
NISR Mode – OFF ON –
ICT104U Mode – ON OFF –
β˜… 5V Enable Mode – OFF OFF –
Reserved – – – ON
β˜… Reserved – – – OFF

Currency assign data (bill value channels)

Which denomination each bill-value channel reports, per interface. Channel numbering differs between interfaces β€” check the column for the interface you are using.

Bill value ICT104U NISR Pulse 5V Enable
BV1 US$ 1 US$ 1 US$ 1 US$ 1
BV2 US$ 5 – US$ 5 US$ 5
BV3 US$ 10 US$ 5 US$ 10 US$ 10
BV4 US$ 20 US$ 10 US$ 20 US$ 20
BV5 US$ 50 US$ 20 US$ 50 US$ 50
BV6 US$ 100 US$ 50 US$ 100 US$ 100
BV7 – US$ 100 – –
Notes printed on the manufacturer sheet
  • β˜… Manufacture setting
  • β—‡ Note : (1) Reset the bill acceptor after setting the dip switch.
  • (2) SW7 and SW8 of the 8-switch DIP and the 4-switch DIP are for pulse protocol only.
  • (3) Interface(VCP) Mode is for USB connection of ICT104U.
  • (4) Diagnostic Mode is for USB connection of Autotest tool.

Not sure which unit you have?

Denomination sets and interfaces vary by configuration part number, printed on the label on the side of the acceptor. Send us a photo of that label and we will confirm the exact model, firmware and correct switch settings β€” contact BillAcceptors.us.